ASTM/Asme A335/SA335 P1, P2, P5, P9, P11, P22, P23, P91, P92 Seamless Alloy Steel Pipe

Product Details
Customization: Available
Technique: Hot Rolled
Material: Alloy Steel
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (30)
Find Similar Products

Basic Info.

Model NO.
ASTM/ASME A335/SA335 P1,P2,P5,P9,P11,P22,P23,P91
Surface Treatment
Black
Usage
Construction & Decoration
Section Shape
Round
A335 Material
ASTM A335 Gr. P5, P9, P11, P12, P21, P22 & P91
Transport Package
Bundle, Wooden Box
Trademark
C&N
Origin
China
Production Capacity
1000tons/Month

Product Description

Description: Alloy steel pipe, alloy seamless steel pipe, alloy welded pipe,seamless alloy steel pipe,alloy pipe,alloy steel tube 
  
Standard:ASTM A335,JIS G3458,JIS A3462,DIN17175,GB5310,GB9948 
ASTM/AME  A335 P1/P5/P9/P11/P12/P22/ P91/P92 Seamless Ferritic Alloy-Steel Pipe for High-Temperature Service 
Material:ASTM A335 P2, ASTM A335 P12, ASTM A335 P11, ASTM A335 P22, ASTM A335 P5, ASTM A335 P91, ASTM A335 P92. 
Outside Diameter:6 mm~600mm 
Wall thickness:2mm~60mm 

 

 

Chemical Composition(%):

Grade
UNS Designation Composition, %
Carbon Manganese Phosphorus, Sulfur Silicon Chromium Molybdenum Others
P1 K11522 0.10-0.20 0.30-0.80 0.025 max 0.025 max 0.10-0.50 --- 0.44-0.65 ---
P2 K11547 0.10-0.20 0.30-0.61 0.025 max 0.025 max 0.10-0.30 0.50-0.81 0.44-0.65 ---
P5 K41545 0.15 max 0.30-0.60 0.025 max 0.025 max 0.50 max 4.00-6.00 0.45-0.65 ---
P9 S50400 0.15 max 0.30-0.60 0.025 max 0.025 max 0.25-1.00 8.00-10.00 0.90-1.10 ---
P11 K11597 0.05-0.15 0.30-0.60 0.025 max 0.025 max 0.50-1.00 1.00-1.50 0.44-0.65 ---
P12 K11562 0.05-0.15 0.30-0.61 0.025 max 0.025 max 0.50 max 0.80-1.25 0.44-0.65 ---
P15 K11578 0.05-0.15 0.30-0.60 0.025 max 0.025 max  1.15-1.65 --- 0.44-0.65 ---
P21 K31545 0.05-0.15 0.30-0.60 0.025 max 0.025 max 0.50 max 2.65-3.35 0.80-1.06 ---
P22 K21590 0.05-0.15 0.30-0.60 0.025 max 0.025 max 0.50 max 1.90-2.60 0.87-1.13 ---
P23 K41650 0.04-0.10 0.10-0.60 0.03 0.01 0.50 max 1.90-2.60 0.05-0.30 V 0.20-0.30
Cb 0.02-0.08
B 0.0005-0.006
N 0.030 max
Al 0.030 max
W 1.45-1.75
P91 K91560 0.08-0.12 0.30-0.60 0.02 0.01 0.20-0.50 8.00-9.50 0.85-1.05 V 0.18-0.25
N 0.030-0.070
Ni 0.40 max
Al 0.04 max
Cb 0.06-0.10
P92 K92460 0.07-0.13 0.30-0.60 0.02 0.01 0.50 max 8.50-9.50 0.30-0.60 V 0.15-0.25
N 0.03-0.07
Ni 0.40 max
Al 0.04 max
Cb 0.04-0.09
W 1.5-2.00
B 0.001-0.006

Mechanical Properties

Data

Grade P11, P22, P5, P9

Grade P91

Grade P92

Tensile strength, min, (MPa)

415

585

620

Yield strength, min, (MPa)

205

415

440

Elongation, min, (%), L/T

30/20

20/

20/

 

Heat Treatment

A / N+T

N+T / Q+T

N+T

Material & Manufacture
Pipe may be either hot finished or cold drawn with the finishing heat treatment noted below.
Heat Treatment Requirements

Grade

Heat Treatment Type 
P5, P9, P11, and P22

Normalizing Temperature Range F [C]

Subcritical Annealing or Tempering 
Temperature Range F [C]

P5 (b,c)

Full or Isothermal Anneal

 

 

 

Normalize and Temper

*****

1250 [675]

 

Subcritical Anneal (P5c only)

*****

1325 - 1375 [715 - 745]

P9

Full or Isothermal Anneal

 

 

 

Normalize and Temper

*****

1250 [675]

P11

Full or Isothermal Anneal

 

 

 

Normalize and Temper

*****

1200 [650]

P22

Full or Isothermal Anneal

 

 

 

Normalize and Temper

*****

1250 [675]

P91

Normalize and Temper

1900-1975 [1040 - 1080]

1350-1470 [730 - 800]

 

Quench and Temper

1900-1975 [1040 - 1080]

1350-1470 [730 - 800]

 
Mechanical Tests Specified
Transverse or Longitudinal Tension Test and Flattening Test, Hardness Test, or Bend Test 
For material heat treated in a batch-type furnace, tests shall be made on 5% of the pipe from each treated lot. For small lots, at least one pipe shall be tested. 
For material heat treated by the continuous process, tests shall be made on a sufficient number of pipe to constitute 5% of the lot, but in no case less than 2 pipe.
Notes for Hardness Test: 
P91 shall not have a hardness not exceeding 250 HB/265 HV [25HRC].
Notes for Bend Test: 
For pipe whose diameter exceeds NPS 25 and whose diameter to wall thickness ratio is 7.0 or less shall be subjected to the bend test instead of the flattening test. 
Other pipe whose diameter equals or exceeds NPS 10 may be given the bend test in place of the flattening test subject to the approval of the purchaser. 
The bend test specimens shall be bent at room temperature through 180 without cracking on the outside of the bent portion.
Hydrostatic Test
The inside diameter of the bend shall be 1 inch [25 mm]. 
Each length of pipe shall be Hydro tested, at option of manufacture nondestructive electric testing can be used.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed